Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Lancet Reg Health Am ; 19: 100449, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36844610

RESUMO

Background: Schools are high-risk settings for SARS-CoV-2 transmission, but necessary for children's educational and social-emotional wellbeing. Previous research suggests that wastewater monitoring can detect SARS-CoV-2 infections in controlled residential settings with high levels of accuracy. However, its effective accuracy, cost, and feasibility in non-residential community settings is unknown. Methods: The objective of this study was to determine the effectiveness and accuracy of community-based passive wastewater and surface (environmental) surveillance to detect SARS-CoV-2 infection in neighborhood schools compared to weekly diagnostic (PCR) testing. We implemented an environmental surveillance system in nine elementary schools with 1700 regularly present staff and students in southern California. The system was validated from November 2020 to March 2021. Findings: In 447 data collection days across the nine sites 89 individuals tested positive for COVID-19, and SARS-CoV-2 was detected in 374 surface samples and 133 wastewater samples. Ninety-three percent of identified cases were associated with an environmental sample (95% CI: 88%-98%); 67% were associated with a positive wastewater sample (95% CI: 57%-77%), and 40% were associated with a positive surface sample (95% CI: 29%-52%). The techniques we utilized allowed for near-complete genomic sequencing of wastewater and surface samples. Interpretation: Passive environmental surveillance can detect the presence of COVID-19 cases in non-residential community school settings with a high degree of accuracy. Funding: County of San Diego, Health and Human Services Agency, National Institutes of Health, National Science Foundation, Centers for Disease Control.

2.
medRxiv ; 2023 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-34704096

RESUMO

Background: Schools are high-risk settings for SARS-CoV-2 transmission, but necessary for children's educational and social-emotional wellbeing. Previous research suggests that wastewater monitoring can detect SARS-CoV-2 infections in controlled residential settings with high levels of accuracy. However, its effective accuracy, cost, and feasibility in non-residential community settings is unknown. Methods: The objective of this study was to determine the effectiveness and accuracy of community-based passive wastewater and surface (environmental) surveillance to detect SARS-CoV-2 infection in neighborhood schools compared to weekly diagnostic (PCR) testing. We implemented an environmental surveillance system in nine elementary schools with 1700 regularly present staff and students in southern California. The system was validated from November 2020 - March 2021. Findings: In 447 data collection days across the nine sites 89 individuals tested positive for COVID-19, and SARS-CoV-2 was detected in 374 surface samples and 133 wastewater samples. Ninety-three percent of identified cases were associated with an environmental sample (95% CI: 88% - 98%); 67% were associated with a positive wastewater sample (95% CI: 57% - 77%), and 40% were associated with a positive surface sample (95% CI: 29% - 52%). The techniques we utilized allowed for near-complete genomic sequencing of wastewater and surface samples. Interpretation: Passive environmental surveillance can detect the presence of COVID-19 cases in non-residential community school settings with a high degree of accuracy. Funding: County of San Diego, Health and Human Services Agency, National Institutes of Health, National Science Foundation, Centers for Disease Control.

3.
Front Neurosci ; 16: 867192, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35706689

RESUMO

Brain-inspired Hyper-dimensional(HD) computing is a novel and efficient computing paradigm. However, highly parallel architectures such as Processing-in-Memory(PIM) are bottle-necked by reduction operations required such as accumulation. To reduce this bottle-neck of HD computing in PIM, we present Stochastic-HD that combines the simplicity of operations in Stochastic Computing (SC) with the complex task solving capabilities of the latest HD computing algorithms. Stochastic-HD leverages deterministic SC, which enables all of HD operations to be done as highly parallel bitwise operations and removes all reduction operations, thus improving the throughput of PIM. To this end, we propose an in-memory hardware design for Stochastic-HD that exploits its high level of parallelism and robustness to approximation. Our hardware uses in-memory bitwise operations along with associative memory-like operations to enable a fast and energy-efficient implementation. With Stochastic-HD, we were able to reach a comparable accuracy with the Baseline-HD. Furthermore, by proposing an integrated Stochastic-HD retraining approach Stochastic-HD is able to reduce the accuracy loss to just 0.3%. We additionally accelerate the retraining process in our hardware design to create an end-to-end accelerator for Stochastic-HD. Finally, we also add support for HD Clustering to Stochastic-HD, which is the first to map the HD Clustering operations to the stochastic domain. As compared to the best PIM design for HD, Stochastic-HD is also 4.4% more accurate and 43.1× more energy-efficient.

4.
mSystems ; 7(2): e0137821, 2022 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-35293792

RESUMO

Increasing data volumes on high-throughput sequencing instruments such as the NovaSeq 6000 leads to long computational bottlenecks for common metagenomics data preprocessing tasks such as adaptor and primer trimming and host removal. Here, we test whether faster recently developed computational tools (Fastp and Minimap2) can replace widely used choices (Atropos and Bowtie2), obtaining dramatic accelerations with additional sensitivity and minimal loss of specificity for these tasks. Furthermore, the taxonomic tables resulting from downstream processing provide biologically comparable results. However, we demonstrate that for taxonomic assignment, Bowtie2's specificity is still required. We suggest that periodic reevaluation of pipeline components, together with improvements to standardized APIs to chain them together, will greatly enhance the efficiency of common bioinformatics tasks while also facilitating incorporation of further optimized steps running on GPUs, FPGAs, or other architectures. We also note that a detailed exploration of available algorithms and pipeline components is an important step that should be taken before optimization of less efficient algorithms on advanced or nonstandard hardware. IMPORTANCE In shotgun metagenomics studies that seek to relate changes in microbial DNA across samples, processing the data on a computer often takes longer than obtaining the data from the sequencing instrument. Recently developed software packages that perform individual steps in the pipeline of data processing in principle offer speed advantages, but in practice they may contain pitfalls that prevent their use, for example, they may make approximations that introduce unacceptable errors in the data. Here, we show that differences in choices of these components can speed up overall data processing by 5-fold or more on the same hardware while maintaining a high degree of correctness, greatly reducing the time taken to interpret results. This is an important step for using the data in clinical settings, where the time taken to obtain the results may be critical for guiding treatment.


Assuntos
Metagenômica , Software , Metagenômica/métodos , Algoritmos , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Biologia Computacional/métodos
5.
Anesth Analg ; 98(4): 976-981, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15041583

RESUMO

UNLABELLED: Recovery from general anesthesia often involves residual sedation, drowsiness, fatigue, and lack of energy that may last hours to days. Modafinil is a wakefulness-promoting drug approved for patients with excessive daytime sleepiness associated with narcolepsy. We evaluated the effect of single doses of modafinil (200 mg) and placebo in patients recovering from general anesthesia. Thirty-four subjects participated in this prospective, randomized, double-blind study approved by our IRB. Preoperatively, patients were asked to rate various symptoms they had experienced over the previous 24-h using a verbal analog scale (VAS) of 0 to 10 as well as discrete scale when indicated. Postoperatively, once the patient was able to tolerate oral intake and met our institutional discharge criteria, the study drug (modafinil 200 mg or placebo) was administered with a sip of water. Patients were contacted 24 (1) hours after dosing to evaluate postdischarge symptoms. Patients in the placebo group reported significantly more postoperative fatigue (4.8 [3.3] versus 1.4 [1.8]), exhaustion (4.3 [3.3] versus 2.4 [3.1]), or degree of feeling worn out (4.7 [3.6] versus 2.9 [2.4]). Significantly more patients reported moderate to severe fatigue in the placebo group (65% versus 12%). Two major themes of "alertness" and "energy" were expressed by 71% of the patients receiving modafinil versus 18% of those receiving placebo. Patients recovering from general anesthesia can significantly benefit from modafinil. IMPLICATIONS: Modafinil significantly reduces fatigue and improves feelings of alertness and energy in postoperative patients. Patients recovering from general anesthesia can significantly benefit from modafinil administration.


Assuntos
Período de Recuperação da Anestesia , Anestesia Geral/efeitos adversos , Compostos Benzidrílicos/uso terapêutico , Estimulantes do Sistema Nervoso Central/uso terapêutico , Complicações Pós-Operatórias/prevenção & controle , Adolescente , Adulto , Idoso , Procedimentos Cirúrgicos Ambulatórios , Comportamento/efeitos dos fármacos , Cognição/efeitos dos fármacos , Método Duplo-Cego , Fadiga/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modafinila , Dor Pós-Operatória/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/psicologia , Estudos Prospectivos , Fases do Sono/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...